Approval: ATEX II 1G Ex ia IIC + II 1D Ex ia IIIC
Output; Operating: 4-20mA HART; inside + LCD
Housing; Cover Sealing; Cable Entry: T14 Alu IP66/67 NEMA6P; EPDM; M20 gland, T14 = side cover (Ex d > M20 thread)
Sensor Range; Sensor Overload Limit: 2bar/200kPa/30psi abs; 20bar/2MPa/300psi
Calibration; Unit: **Customised; see additional spec.
Membrane Material:316L
Process Connection: Thread ISO228 G1/2 EN837, 316L
Fill Fluid: Silicone oil
Additional Option 1:3.1 Material certificate, wetted metallic parts, EN10204-3.1 inspection certificate
Additional Option 2:SIL