Approval:ATEX II 1/2G Ex ia IIC T6
Output; Operating:4-20mA HART; inside + LCD
Housing; Cover Sealing; Cable Entry:T14 Alu IP66/67 NEMA6P; EPDM; M20 gland, T14 = side cover (Ex d > M20 thread)
Sensor Range; Sensor Overload Limit:2bar/200kPa/30psi gauge; 20bar/2MPa/300psi
Calibration; Unit:Sensor range; mbar/bar
Membrane Material:0.25mm PTFE>316L
Process Connection:DN25 PN10-40 B1, 316L, flush mount, flange EN1092-1 (DIN2527 D)
Transmitter Mounting; Fill Fluid:Direct; vegetable oil
Additional Option 1:Not selected